{"recall":{"id":"fda-device-98876","source":"FDA","sourceName":"U.S. Food and Drug Administration (openFDA device enforcement)","cat":"medicines","kids":false,"kind":"device","title":"Laborie Medical Technologies Corp recalls Solar GI System (Water Perfusion)","firm":"Laborie Medical Technologies Corp","date":"2026-05-21","reported":"2026-07-08","status":"Ongoing","classification":"Class II","products":[{"name":"Solar GI System (Water Perfusion); Product Name (Catalog Number): Solar GI LGI H2O, 12p, Trolley system (G3-6), Solar GI HRM H2O, 24p, Compact Pole system (G3-7), Solar GI HRM H2O, 24p, Trolley system (G3-8), Solar GI HRM H2O, 36p, Trolley system (G3-12), Solar GI HRAM H2O, 24p, Trolley system (G3-14);","code":"1. Catalog Number: G3-6; UDI-DI: Primary UDI-DI: 08717775955047; Basic UDI-DI: 87177759500G3G8; All serial numbers; 2. Catalog Number: G3-7; UDI-DI: Primary UDI-DI: 08717775955054; Basic UDI-DI: 87177759500G3G8; All serial numbers; 3. Catalog Number: G3-8; UDI-DI: Primary UDI-DI: 08717775955061; Basic UDI-DI: 87177759500G3G8; All serial numbers; 4. Catalog Number: G3-12; UDI-DI: Primary UDI-DI: 08717775955078; Basic UDI-DI: 87177759500G3G8; All serial numbers; 5. Catalog Number: G3-14; UDI-DI: Primary UDI-DI: 08717775955085; Basic UDI-DI: 87177759500G3G8; All serial numbers;","quantity":"372 units","number":"Z-2669-2026","classification":"Class II"}],"reason":"Under extended clinical use conditions (e.g., long duration studies), moisture generated within the pneumatic circuit may accumulate inside the system's internal tubing or at the hydrophobic filter and waterproof pressure sensors. Accumulated moisture may affect airflow or pressure measurement performance if not properly removed.","hazard":"FDA Class II: may cause temporary or medically reversible adverse health consequences (FDA definition).","affected":"Worldwide distribution - US Nationwide and the countries of Argentina, Australia, Austria, Bangladesh, Belgium, Canada, China, Costa Rica, Croatia, Cyprus, Czech Republic. Denmark, Egypt, France, Germany, Hong Kong, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jordan, Kuwait, Lebanon, Libya, Lithuania, Malaysia, Namibia, Nepal, Netherlands. Oman, Osterreich, Pakistan, Poland, Portugal, Puerto Rico, Qatar, Russia, Russian Federation, Saudi Arabia, Serbia, Slovenia, South Africa, South Korea, Spain, Sri Lanka, Switzerland, Taiwan, Thailand, Tunisia, Turkey, UAE, United Kingdom, and Vietnam.","nationwide":true,"states":[],"units":"372 units","remedy":"","whatToDo":"Check your product against the names and codes above. The FDA enforcement record lists the recall as voluntary: firm initiated; it does not state a consumer remedy, so follow the firm’s notice or the FDA link.","contact":"","url":"https://www.accessdata.fda.gov/scripts/ires/index.cfm?Event=98876","apiUrl":"https://api.fda.gov/device/enforcement.json?search=report_date:[20260705+TO+20991231]&sort=report_date:desc&limit=1000","rawHash":"31770daa699557dc","firstSeen":"2026-11-02T13:57:14.206Z","updatedAt":"2026-11-02T13:57:14.206Z","history":[]},"official":{"fetchedAt":"2026-11-02T13:57:14.206Z","apiUrl":"https://api.fda.gov/device/enforcement.json?search=report_date:[20260705+TO+20991231]&sort=report_date:desc&limit=1000","officialUrl":"https://www.accessdata.fda.gov/scripts/ires/index.cfm?Event=98876","record":[{"status":"Ongoing","city":"Portsmouth","state":"NH","country":"United States","classification":"Class II","openfda":{},"product_type":"Devices","event_id":"98876","recalling_firm":"Laborie Medical Technologies Corp","address_1":"180 International Dr","address_2":"N/A","postal_code":"03801-6837","voluntary_mandated":"Voluntary: Firm initiated","initial_firm_notification":"Letter","distribution_pattern":"Worldwide distribution - US Nationwide and the countries of Argentina, Australia, Austria, Bangladesh, Belgium, Canada, China, Costa Rica, Croatia, Cyprus, Czech Republic. Denmark, Egypt, France, Germany, Hong Kong, Hungary, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jordan, Kuwait, Lebanon, Libya, Lithuania, Malaysia, Namibia, Nepal, Netherlands. Oman, Osterreich, Pakistan, Poland, Portugal, Puerto Rico, Qatar, Russia, Russian Federation, Saudi Arabia, Serbia, Slovenia, South Africa, South Korea, Spain, Sri Lanka, Switzerland, Taiwan, Thailand, Tunisia, Turkey, UAE, United Kingdom, and Vietnam.","recall_number":"Z-2669-2026","product_description":"Solar GI System (Water Perfusion);   Product Name (Catalog Number): Solar GI LGI H2O, 12p, Trolley system (G3-6), Solar GI HRM H2O, 24p, Compact Pole system (G3-7), Solar GI HRM H2O, 24p, Trolley system (G3-8), Solar GI HRM H2O, 36p, Trolley system (G3-12), Solar GI HRAM H2O, 24p, Trolley system (G3-14);","product_quantity":"372 units","reason_for_recall":"Under extended clinical use conditions (e.g., long duration studies), moisture generated within the pneumatic circuit may accumulate inside the system's internal tubing or at the hydrophobic filter and waterproof pressure sensors. Accumulated moisture may affect airflow or pressure measurement performance if not properly removed.","recall_initiation_date":"20260521","center_classification_date":"20260702","report_date":"20260708","code_info":"1. Catalog Number: G3-6; UDI-DI: Primary UDI-DI: 08717775955047; Basic UDI-DI: 87177759500G3G8; All serial numbers; 2. Catalog Number: G3-7; UDI-DI: Primary UDI-DI: 08717775955054; Basic UDI-DI: 87177759500G3G8; All serial numbers; 3. Catalog Number: G3-8; UDI-DI: Primary UDI-DI: 08717775955061; Basic UDI-DI: 87177759500G3G8; All serial numbers; 4. Catalog Number: G3-12; UDI-DI: Primary UDI-DI: 08717775955078; Basic UDI-DI: 87177759500G3G8; All serial numbers; 5. Catalog Number: G3-14; UDI-DI: Primary UDI-DI: 08717775955085; Basic UDI-DI: 87177759500G3G8; All serial numbers;"}]}}